Housekeeping Series For Desktop/Server

INFSitronix creats next generation trend of housekeeping and provides high integrated series solution from entry to high-end power rate. At the same time, INFSitronix patened on-line trimming can help customer to simplify the production line.

Product selection table

Single channel

PART NO. Package DESCRIPTION OCP OVP UVP OTP FAN Remark
3.3V 5V 12V 3.3V 5V 12V 3.3V 5V 12V
IN1S316 SOP-8 1ch OV/UV/OC Protection V V V V V V V V V
I1501 SOP-14 2ch OV/UV/OC Protection with burst control, two-stage OCP V V V V
I1802 SOP-14 2ch OV/UV/OC Protection with burst control and FCEN signal for FAN mode detected V V V V
I1803A SOP-14 2ch OV/UV/OC Protection with burst control and FCEN signal for FAN mode detected V V V V
I1806 SOP-14 2ch OV/UV/OC Protection with burst control, one-stage OCP V V V
IN1T603 SOP-16 2ch OV/UV/OC Protection with burst control, two-stage OCP V V V
IN1T603B SOP-16 1ch OV/UV/OC Protection with burst control, one-stage OCP V V V
IN1T603D SOP-16 1ch OV/UV/OC Protection with burst control, one-stage OCP V V V
IN1T603E SOP-16 2ch OV/UV/OC Protection with burst control, two-stage OCP V V V
IN1T604 SOP-14 2ch OV/UV/OC Protection with burst control, two-stage OCP V V V
IN1T608 SOP-14 2ch OV/UV/OC Protection with burst control, one-stage OCP and FAN controller V V V V
IN1T701 SOP-14 2ch OV/UV/OC Protection with burst control, one-stage OCP and FAN controller V V V V V
IN1T702 SOP-16 2ch OV/UV/OC Protection, three-stage OCP and FAN controller V V V V V
IN1T705 SOP-14 2ch OV/UV/OC Protection, three-stage OCP and FAN controller V V V V V
IN1T706 SOP-16 3ch OV/UV/OC Protection with burst control V V V
IN1T801 SOP-20 3ch OV/UV/OC Protection, three-stage OCP and FAN controller V V V V V

Multi channel

PART NO. Package Package OCP OVP UVP OTP FAN Remark
3.3V 5V 12V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V
IN1S315X SOP-8 3.3/5/12V OV/UV Protection V V V V V V ST9S313
IN1S315 SOP-8 3.3/5/12V OV/UV Protection V V V V V V ST9S313A
IN1S315B1 SOP-8 3.3/5/12V OV/UV Protection V V V V V ST9S313B1
IN1S315C SOP-8 3.3/5/12V OV/UV Protection V V V V V V ST9S313C
IN1S315I SOP-8 3.3/5/12V OV/UV Protection V V V V V V IN1S313I
ST9S429 SOP-14 3.3/5/12V OV/UV/OC Protection V V V V V V V V V
IN1S429I SOP-14 3.3/5/12V OV/UV/OC Protection V V V V V V V V V
ST9S426 SOP-14 3.3/5/12V OV/UV/OC Protection V V V V V V V V V
ST9S424A SOP-16 3.3/5/12V OV/UV/OC Protection V V V V V V V V V V
IN1S424I SOP-16 3.3/5/12V OV/UV/OC Protection V V V V V V V V V V
IN1S406 SOP-16 3.3/5/12V OV/UV/OC Protection V V V V V V V V V V
IN1T703 SOP-16 3.3/5/12V OV/UV/OC Protection and FAN controller V V V V V V V V V V V
IN1T703I SOP-16 3.3/5/12V OV/UV/OC Protection and FAN controller V V V V V V V V V V V
IN1T707 SOP-16 3.3/5/12V OV/UV/OC Protection and FAN controller V V V V V V V V V V V
IN1S480 SOP-8 48V OV/UV/OC Protection

Server

PART NO. Package DESCRIPTION Remark
IN1S012 SOP-8 2ch OV/UV/OC Protection
IN1S015 SOP-8 Oring MOSFET controller

Desktop Housekeeping Milestones

2nd Generation 3rd Generation 4th Generation 5th Generation 6th Generation-48V
No Standby PSU No Standby PSU No Standby PSU
Protection Protection Auto
Trim
(OCP)
Protection Auto
Trim
(OCP)
Protection Auto
Trim
(OCP)
Protection Auto
Trim
(OCP)
Feedback Feedback Feedback Feedback Feedback
-Fan Control
-OTP
-Reference (TL431)
-Meter
-SR Buck D2D
-Fan/OTP -Single O/P 12V+
-Burst mode command(400W within)
-Single O/P 12V+
-Burst mode command(400W 以內)
-Single O/P 12V+
-Burst mode command(400W 以內)
-Meter/Burst-in/out -Meter/Burst-in/out -Meter/Burst-in/out
-Auto Fan Curve Fitting -Auto Fan Curve Fitting
-Communication (1-wire, 12C, PMBUS)
-Wide Range ≥ 48V Module for Powerful GPU

Auto-OCP/Fan Curve

What Can do about Auto OCP?

    • Traditional manufacture flow
      • INT set 20A level (for example)  artificial regulate VR to latch mode  glue fix
    • Drawback
      • VR regulate need additional main-power
      • ageing
        • Glue crack, VR loose, ….etc
    • Proposal
      • Supervisor integrate Infinno Smart-auto-trim™ algorithm
      • Change VR stage to IC auto trim test methodology
    • Advantage (Automation)
      • Keep current manufacture flow
      • Skip the risk of ageing of VR
      • Skip OCP regulation time

What Can do about Auto Fan?

    • Auto Fan curve setting
    • Auto Fan Curve Design Tool
    • Online fan curve adjusted
    • Easy fan curve debug by debug mode